Part No | Part Type | Description | QTY | RFQ |
---|---|---|---|---|
DIP12-1A72-10C | reed relay | dry reed relay, spst, momentary, 0.014a (coil), 16vdc (coil), 145mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
HM12-1B83-20-6 | relay | reed relays high volt reed relay b-nc 50w 3v 12vdc dry reed relay | Avl | RFQ |
BE24-2B71-M | reed relay | dry reed relay, dpst, momentary, 0.01a (coil), 24vdc (coil), 276mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
8824271600 | reed relay | dry reed relay, dpst, momentary, 0.01a (coil), 24vdc (coil), 276mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
3205172011 | reed relay | dry reed relay, spst, momentary, 0.01a (coil), 5vdc (coil), 50mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
DIP15-1B72-19Q | reed relay | dry reed relay, spst, momentary, 0.009a (coil), 20vdc (coil), 115mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
DIP24-1A75-13M | reed relay | dry reed relay, spst, momentary, 0.014a (coil), 30vdc (coil), 290mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | Avl | RFQ |
9005185400 | reed relay | dry reed relay, spst, momentary, 0.063a (coil), 5vdc (coil), 315mw (coil), 1a (contact), 1000vdc (contact), through hole-straight mount | Avl | RFQ |
DIP15-1A72-10C | reed relay | dry reed relay, spst, momentary, 0.009a (coil), 20vdc (coil), 115mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
DIP24-1C90-51Q | reed relay | dry reed relay, spdt, momentary, 0.014a (coil), 30vdc (coil), 290mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount | Avl | RFQ |
MK22-B-2 | NA | NA | Avl | RFQ |
MRX05-2A79 | reed relay | dry reed relay, dpst, momentary, 0.02a (coil), 5vdc (coil), 100mw (coil), through hole-straight mount | Avl | RFQ |
1305166115 | reed relay | dry reed relay, spst, momentary, 0.011a (coil), 5vdc (coil), 55mw (coil), 0.5a (contact), 180vdc (contact), through hole-straight mount | Avl | RFQ |
SIL24-1A72-71L | reed relay | reed relays 1 form a, spst-no 24v sil dry reed relay, spst, momentary, 0.012a (coil), 24vdc (coil), 290mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
8524169152 | reed relay | dry reed relay | Avl | RFQ |
MK13-1C90C-500W | resistors | sensor magnetic flat pack meder electronicsensor magnetic flat pack | Avl | RFQ |
SIL05-1A31-71D | reed relay | dry reed relay, spst, momentary, 0.062a (coil), 5vdc (coil), 312mw (coil), 2a (contact), 500vdc (contact), through hole-straight mount | Avl | RFQ |
MRX12-1C90 | reed relay | reed relays ex-approved relays 1 form c, spdt, 12v dry reed relay, spdt, momentary, 0.009a (coil), 12vdc (coil), 110mw (coil), 0.24a (contact), 28vdc (contact), through hole-straight mount | Avl | RFQ |
RM05-8-BV09774 | NA | inventory r | Avl | RFQ |
047170 | NA | NA | Avl | RFQ |
1305600030 | reed relay | dry reed relay | Avl | RFQ |
DIL-CL-1A81-15-513M | reed relay | dry reed relay, spst, momentary, 0.5a (contact), 90vdc (contact), through hole-straight mount | Avl | RFQ |
9231350022 | NA | 2 days to us, rohs, 100% new | Avl | RFQ |
1912169114 | reed relay | dry reed relay, spst, momentary, 0.052a (coil), 12vdc (coil), 620mw (coil), 3a (contact), 10000vdc (contact), through hole-straight mount | Avl | RFQ |
DIL12-2C90-60L | reed relay | dry reed relay | Avl | RFQ |
3205172010 | reed relay | dry reed relay, spst, momentary, 0.01a (coil), 5vdc (coil), 50mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
LI24-1A66 | reed relay | dry reed relay, spst, momentary, 0.007a (coil), 24vdc (coil), 159mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
4003004029 | NA | 2 days to us, rohs, 100% new | Avl | RFQ |
SIL03-1A72-71D | reed relay | reed relays form a - no 10 w, 200 v dry reed relay, spst, momentary, 0.006a (coil), 3vdc (coil), 18mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
SIL05-1A8576L3K | reed relay | dry reed relay, spst, momentary, 0.023a (coil), 5vdc (coil), 114mw (coil), 1a (contact), 1000vdc (contact), through hole-straight mount | Avl | RFQ |
RM05-8A-S | reed relay | dry reed relay, momentary, 0.01a (coil), 5vdc (coil), 10mw (coil), 0.5a (contact), 170vdc (contact), through hole-straight mount | Avl | RFQ |
073674 | NA | NA | Avl | RFQ |
MS05-1A87-75L | reed relay | reed relays 1 form a 5 v micro sil dry reed relay, spst, momentary, 0.018a (coil), 5vdc (coil), 90mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
DIP24-1B72-19L | reed relay | dry reed relay, spst, momentary, 0.014a (coil), 30vdc (coil), 290mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
SIL05BV500 | NA | 06 | Avl | RFQ |
DIP05-1B66-19L | reed relay | dry reed relay, spst, momentary, 0.01a (coil), 5vdc (coil), 50mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
DIP12-1C90-51S | reed relay | dry reed relay, spdt, momentary, 0.029a (coil), 16vdc (coil), 115mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount | Avl | RFQ |
BE05-1A71-V | reed relay | dry reed relay, spst, momentary, 0.014a (coil), 5vdc (coil), 72mw (coil), 0.5a (contact), 180vdc (contact), through hole-straight mount | Avl | RFQ |
8524169002 | reed relay | dry reed relay, spst, momentary, 0.052a (coil), 24vdc (coil), 1240mw (coil), 3a (contact), 10000vdc (contact), through hole-straight mount | Avl | RFQ |
1312100015 | reed relay | dry reed relay, spst, momentary, 0.006a (coil), 12vdc (coil), 72mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
DIL05-1A71-13L | reed relay | dry reed relay | Avl | RFQ |
9240000031 | NA | 2 days to us, rohs, 100% new | Avl | RFQ |
HI12-1A85 | reed relay | relay reed spst-no 1a 12v reed non latching 13ma 12vdc spst-no (1 form a) 1a 1000vac 1000vdc - max 8.4 vdc 1.8 vdc high insulation resistance through hole pc pin bulk dry reed relay | Avl | RFQ |
DIL05-1A71-10A | reed relay | dry reed relay | Avl | RFQ |
CRF05-1A | relays | relay rf spst 500ma 5v rf non latching 33.3ma 5vdc spst-no (1 form a) 500ma 170vac 170vdc - max 3.75 vdc 0.75 vdc - surface mount smd (smt) tab digi-reel« reed relays 1 form a 5v smt high frequency | Avl | RFQ |
MK23-35-B-4 | NA | NA | Avl | RFQ |
SIL05BV07056 | NA | 01 | Avl | RFQ |
BE12-2A66-M | reed relay | dry reed relay, dpst, momentary, 0.014a (coil), 16vdc (coil), 1100mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
086326 | NA | NA | Avl | RFQ |
3224190851 | reed relay | dry reed relay, spdt, momentary, 0.012a (coil), 24vdc (coil), 288mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount | Avl | RFQ |
8812485200 | reed relay | dry reed relay, 4pst, momentary, 0.046a (coil), 12vdc (coil), 554mw (coil), 1a (contact), 1000vdc (contact), through hole-straight mount | Avl | RFQ |
DIL05-1A66-13D | reed relay | dry reed relay | Avl | RFQ |
DIL24-1A66-10L | reed relay | dry reed relay | Avl | RFQ |
SIL05-1A75-71Q | reed relay | dry reed relay, spst, momentary, 0.025a (coil), 5vdc (coil), 125mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | Avl | RFQ |
1305190051 | reed relay | dry reed relay | Avl | RFQ |
DIL-CL-K100-9-15 | NA | inventory r | Avl | RFQ |
DIL05-2A71-21R | reed relay | dry reed relay, dpst, momentary, 0.025a (coil), 5vdc (coil), 125mw (coil), 0.5a (contact), 180vdc (contact), through hole-straight mount | Avl | RFQ |
8812271400 | reed relay | dry reed relay, dpst, momentary, 0.032a (coil), 12vdc (coil), 389mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
MK16-C-1 | NA | reed sensor, 1 form a, spst-no, flat leads/slot mounting at | Avl | RFQ |
3224001051 | reed relay | dry reed relay, spdt, momentary, 0.012a (coil), 24vdc (coil), 288mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount | Avl | RFQ |
HF24-1A54-7 | reed relay | dry reed relay, spst, momentary, 0.024a (coil), 24vdc (coil), 575mw (coil), 1.5a (contact), 500vdc (contact), through hole-straight mount | Avl | RFQ |
MS05-1B87-80L | reed relay | dry reed relay, spst, momentary, 0.013a (coil), 5vdc (coil), 67mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
DIP24-1A72-12A | reed relay | dry reed relay, spst, momentary, 0.014a (coil), 30vdc (coil), 290mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
DIP12-2A72-21E | reed relay | dry reed relay, dpst, momentary, 0.029a (coil), 16vdc (coil), 290mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | Avl | RFQ |
DIP24-1A75-11L | reed relay | dry reed relay, spst, momentary, 0.014a (coil), 30vdc (coil), 290mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | Avl | RFQ |
086744 | NA | NA | Avl | RFQ |
1305100211 | reed relay | dry reed relay | Avl | RFQ |
CRR05-1BS | reed relay | dry reed relay, spst, momentary, 0.026a (coil), 5vdc (coil), 129mw (coil), 0.5a (contact), 170vdc (contact), surface mount-straight | Avl | RFQ |
LP05-1A71-80V | reed relay | dry reed relay, spst, momentary, 0.022a (coil), 5vdc (coil), 109mw (coil), 0.5a (contact), 180vdc (contact), through hole-straight mount | Avl | RFQ |
DIL12-1A71-13L | reed relay | dry reed relay | Avl | RFQ |